Septic mole

23-09-2018
Sewage

The issue of organizing the disposal of waste at a dacha plot or in living conditions in a private household is almost always urgent. One solution to this issue could be a simple cesspool, but if the site cannot boast of extensive territories, the pit is not always appropriate. In addition, with this option, it is possible for sewage to penetrate into the soil or groundwater. An excellent way out of this situation would be to install a special cleaning device at the site, such as the septic tank Mole. Some aspects of the work, as well as its characteristics, will be discussed further.

The principle of operation of the septic tank

The principle of operation and the device septic tank

First you need to say a few words about what a septic tank is. This device, which is intended for the collection and purification of discharged waste, as well as their primary processing.

A septic tank consists of one or more chambers in which the collection, accumulation and fermentation of biological waste occurs. One of the key features of the septic tank Mole is the possibility of separate input of the so-called "gray" waste, that is, for example, water from a washing machine. In this case, the discharge is made immediately to the second tank, bypassing the stage of splitting into fractions. It should be noted that the presence of several chambers is possible only in the case of a vertical execution of the cleaning device. If the septic tank is made in a horizontal version, the chamber will be the only one, however, the design provides for the possibility of sequential connection of two or more septic tanks, resulting in a multi-chamber cleaning system that, in addition to operating efficiency, will cope with large volumes of wastewater.

As for the principle of operation of the septic tank, here it must be said that it is not too different from other manufacturing options for such devices:

  • Discharged waste enters the receiving chamber.
  • Inside it, the total mass is divided into fractions - larger and heavier elements settle to the bottom, and small ones mixed with liquid are poured through the valve into the second chamber.
  • There, a secondary separation is performed and the waste is recycled by bacteria, and the liquid goes on.
  • The liquid passes through a special filter and is removed outside the septic tank. There it passes through the drainage and is finally cleaned.

The liquid coming out of the septic tank has practically no pollution, and therefore does not harm either the soil or the waters into which it can get.

Due to the fact that the device septic Mole is simple and functional, problems during operation should not arise. In addition, it is worth taking into account the fact that the septic tank of the configuration in question requires minimal effort during installation. The whole structure is enclosed in a frost-resistant, durable plastic case, which, with large useful volumes, has rather compact dimensions.

In addition, the preparatory work required for the installation of such a septic tank will also be minimal. It is enough to dig a foundation pit of sufficient depth and after installing the septic tank to cover it with sand. Techniques require a minimum, which, together with the points mentioned above, entails a general reduction in investment.

Installation rules

Septic installation

Consideration of the issue would be incomplete without mentioning the rules, according to which the installation work should be carried out:

  • It is necessary to take into account the depth of groundwater. Especially this question is relevant in the vertical version of the septic tank.
  • If a separate supply of “gray” drains is planned, then installation of a separate pipeline or the possibility of overlapping the drain on the riser will be required.
  • Despite the resilience of the manufacture of the body of the septic tank to the effects of low temperatures, the possibility of cracking remains. To avoid such situations, it is better to warm the septic tank with special materials. This is especially true for the northern regions.
  • In order to avoid freezing of sewage pipes, it is better to place a septic tank no further than 15 meters from the exit point of the riser to the outside. For the same reason, do not make a large number of bends in the pipeline.
  • When choosing an installation site, it is necessary to take into account the need for free access of equipment. The same rule is relevant for the further maintenance of the device.

The lineup

Horizontal Septic Tank Mole

Among other things, a few words can be said about the diversity of models of septic tanks Mole. As mentioned above, there are horizontal or vertical versions of the septic tanks. Their main difference lies in the fact that the vertical design is likely to be multi-chamber. This greatly expands the range of capabilities of the device, but also increases its price. The horizontal execution of a septic tank is characterized by a single-chamber device.

Septic Mole vertical

The vertical Mole septic tank can be represented by the Mole 1.8 and Mole 3.6 models. As the name implies, the working volume of devices is 1.8 m3 and 3.6 m3 respectively. By the way, the second model often has 3 cameras and is distinguished by an elliptical body shape, while a smaller septic tank has a cylindrical shape. Horizontal models are always single-chamber and have a volume of 1.17 m.3.

In conclusion, it is worth adding that the septic tank Mole received positive feedback from both experts and ordinary users, having established itself as a simple, reliable, but at the same time functional and effective waste treatment device. Its installation is recommended for both dacha plots and owners of private cottages.

Video

Watch a video about mounting a horizontal septic tank Mole: